Skip to content
Cost Guide9 min read

What It Costs to Set Up an Office Network in Pakistan

The switch is rarely the expensive part. Cabling, containment and the labelling nobody quotes for are where the budget actually goes.

Published 11 June 2026
Structured cabling patch panel and network switches in an office comms rack

Network quotations in Pakistan are difficult to compare because suppliers itemise them differently, and the largest cost is the one that varies most between sites. Here is what actually drives the number.

The cost is in the cable, not the box

This surprises people. A managed switch and a couple of access points are a known, comparable cost. Running cable through a finished building is not.

The variables that matter:

  • Does containment already exist? Existing trunking or conduit can halve the labour.
  • Is the building finished? Chasing walls and making good afterwards is skilled work and it is slow.
  • Construction type. Solid brick and reinforced concrete — normal across much of Pakistan — is dramatically slower to route through than partition walls.
  • Run lengths. Distance to the comms room per outlet, not floor area.
  • Working hours. Occupied premises frequently mean evening or weekend work.

A supplier who quotes your network without walking the building is guessing at the single largest cost in the project. That is why two quotations for “the same” job can differ by a factor of two and both be honest.

What a proper network installation includes

Component What it covers
Site survey Outlet positions, cable routes, comms room location, constraints
Structured cabling Cat6 / Cat6A to each outlet, in containment
Termination Patch panels, wall outlets, patch leads
Certification testing Per-run testing to category standard, with a report
Labelling Both ends of every run, to a consistent scheme
Switching Managed switches with PoE budget headroom
Wireless Access points, placed by survey not by calculator
Configuration VLANs, addressing, segmentation, failover
Documentation Rack diagram, port schedule, VLAN and IP table

The three items in bold are the ones most commonly deleted to hit a price, and they are the ones you will miss most.

Why labelling is worth paying for

Almost every network fault we are called to in Pakistan traces back to the same origin: nobody labelled anything and no drawing exists.

The switch is rarely the problem. What costs money is the two days an engineer spends tracing an unlabelled bundle to work out which of forty identical grey cables goes to the accounts office. You pay that cost every time something goes wrong, for the entire life of the installation.

Labelling and documentation add roughly one engineer-day to a typical office installation. It is the highest-return hour in the whole project.

Certification versus continuity testing

These are not the same thing and the distinction matters.

A continuity test confirms the cable is connected end to end. A cheap tester does this in seconds.

A certification test measures the cable’s actual performance against the category standard — attenuation, crosstalk, return loss — and produces a per-run report.

A cable can pass continuity and fail certification. It will work fine on a lightly loaded network and produce intermittent, maddening problems under load. Insist on certification results as a deliverable. It is also the only evidence that lets you hold anyone accountable later.

Sizing the switch properly

Two numbers matter beyond port count:

PoE budget. Every access point, camera and IP phone draws from it. A switch sized exactly for today’s access points will not carry the cameras you add in year two, and replacing a switch is far more expensive than specifying headroom initially.

Uplink capacity. If every desk is gigabit and the uplink to the server or router is also gigabit, that uplink is your bottleneck the moment several people move large files.

Wireless in Pakistani buildings

Vendor coverage calculators are built on assumptions about open-plan offices with partition walls. A great deal of commercial and institutional building stock in Pakistan — and particularly in Peshawar and across KPK — is solid brick or reinforced concrete with thick internal walls.

Signal a calculator predicts will cover four rooms frequently covers one and a half.

Practical guidance:

  • Start at one access point per twenty to twenty-five concurrent users, then adjust upward for construction
  • Survey rather than model for anything beyond a small single-floor office
  • Do a post-installation coverage walk in the rooms that matter, not in the corridor
  • For exam halls, boardrooms or anywhere reliability is genuinely critical, plan for higher density than the general figure

Segmentation: build it in

Guest WiFi on the same network as your finance systems is a real exposure, and it is startlingly common in offices that grew organically.

Separating guest, staff, surveillance and management traffic onto their own VLANs at installation is straightforward and adds very little cost. Retrofitting it across a live network later is disruptive and usually triggered by an audit finding rather than by choice.

If you are putting CCTV on the same infrastructure, this stops being optional.

Getting quotations you can compare

Ask every supplier to itemise:

  1. Survey — included or not
  2. Cable category and estimated total run length
  3. Containment — new, existing, or making good required
  4. Certification testing — included, with report provided?
  5. Labelling scheme and documentation deliverables
  6. Switch model, port count and spare PoE budget
  7. Access point count and how it was determined
  8. Configuration scope — VLANs, failover, QoS
  9. Out-of-hours working, if the premises are occupied

If one quotation is dramatically cheaper, the difference is almost always in items 4, 5 and 8. Ask specifically.

If you are fitting out a new office

Bring your network supplier in while the fit-out is at planning stage, before partitions go up. The cost difference between running containment during a fit-out and retrofitting it into a finished office is substantial, and the same applies to power provision for the comms rack.

An IT supplier brought in after the office is finished routinely adds cost and produces visible trunking nobody wanted. We cover this on our corporate and SME page.


Send us a floor plan — even a rough sketch — and a headcount, and we will come back with outlet positions, switch sizing, access point placement and a cabling estimate for your actual building. Request a quote.

Quick Answers

Questions on this topic

What does it cost to network a 20-person office in Pakistan?

The dominant variable is cabling, not equipment. For a twenty-person office in a building with existing containment, a managed switch, business-grade wireless and certified Cat6 cabling to each desk is a mid-six-figure rupee project. The same office in a finished building with no cable routes — where walls need chasing and trunking installed — can be substantially more, because you are paying for labour and making good rather than hardware. This is why remote quotations for network installation are unreliable.

Is Cat6 worth the extra cost over Cat5e?

Almost always, because the cable is a modest premium and the labour to install it is identical. Since you are paying an engineer to run cable through walls and containment either way, specifying Cat6 costs relatively little extra and gives headroom for multi-gigabit equipment later. What is not worth doing is re-pulling existing serviceable Cat5e purely on specification grounds — if it certifies at gigabit and your equipment is gigabit, it is doing its job.

How many WiFi access points does an office need?

Concurrent device density drives the answer, not floor area. As a starting point, plan one access point per twenty to twenty-five concurrent users in a normal office environment, then adjust upward for building construction. In Pakistan that adjustment is usually significant — load-bearing brick and reinforced concrete attenuate signal far more than the drywall assumed in vendor coverage calculators, so counts derived from square metres consistently come out short.

Do we need a managed switch for a small office?

For under about ten people with no guest network and no cameras sharing the infrastructure, an unmanaged switch is genuinely adequate. Managed switching earns its cost the moment you need to separate guest WiFi from business systems, put surveillance on the network, or diagnose a fault without physically visiting the rack. On current hardware the price difference is smaller than most buyers expect, and retrofitting segmentation onto a flat network later is considerably more disruptive than building it in.

Related pages

Where this topic connects to what we actually supply.

Get Started

Have a requirement this guide relates to?

Send us the specification, the BOQ or just the problem. You will get an itemised quotation with lead times and warranty terms — typically within 48 hours.